Bell System bellview Specifikace Strana 7

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 27
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 6
Bell View Video Entry System 1 Way
5
Important Safety Information
Connections to the 240V AC mains supply must be carried out by a qualified electrician
or similar competent person, and made in accordance with accepted safety practices.
A two-pole switch (as provided by a Consumer Unit or Switch-Fuse) must be included
to isolate both Live and Neutral during Installation or Maintenance. The circuit must be
protected by a fuse or other current-limiting device, rated according to the capacity of
the cable used, up to a maximum of 10A. Use only mains cable to BS6004 or
equivalent, within the following specified limits:
Min Max
Conductor Diameter 1.0mm (0.8mm
2
) 2.25mm (4mm
2
)
Cable Diameter 4.0mm 8.0mm
The M540 power supply is fitted with an internal mains fuse; always replace with the
correct type and rating. The fuse must be of the 20mm glass type, approved to BS EN
60127 or equivalent:
T250mA 250V ( 250mA, 250V, Time delay)
Environment
All equipment except the entrance panel must be placed in a protected indoor
environment.
Video Telephone
The display module of the video telephone has a high voltage circuit (2KV) which
represents a shock hazard. When the top cover of the telephone is removed,
precautions must be taken to avoid contact with this module.