Bell System CS106 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Numerické klávesnice Bell System CS106. C106 Coded Access Keypad CS106 Door Entry & Coded Entry Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 23
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
C106
CodedAccessKeypad
CS106
DoorEntry&CodedEntry
Including:
PD-024Issue3
BellSystem(Telephones)Ltd.
PresleyWay,CrownHill,MiltonKeynesMK80ET.
Tel:01908261106FAX:01908261116
email:[email protected]kwebsite:www.bellsystem.co.uk
Zobrazit stránku 0
1 2 3 4 5 6 ... 22 23

Shrnutí obsahu

Strany 1 - DoorEntry&CodedEntry

C106CodedAccessKeypadCS106DoorEntry&CodedEntryIncluding:PD-024Issue3BellSystem(Telephones)Ltd.PresleyWay,CrownHill,MiltonKeynesMK80ET.Tel:01908261

Strany 2 - Products

C106 Keypad17Choosing an access codeTo ensure an adequate level of security it is recommended that a minimum of 4digits be used for each access code,

Strany 3 - General Description

C106 Keypad19Procedure— Enter the security key.— Type : <51 - 60> * <Action No> #— Both LEDs flash once— Exit program mode bypressing **Ex

Strany 4

C106 Keypad21Programming a Lock Delay Time (Function 96)This function causes a delay (0-99 seconds) to be introduced between thetriggering of the lock

Strany 5 - Installation

C106 Keypad23Summary of Program FunctionsTable 1 - Programming Access CodesNo. Function Key sequence Factory Setting1 Program Code 11 * <1-8 digits

Strany 6

C106 Keypad25Table 4 - Programming of Other FunctionsNo Function Key Sequence Factory Setting91 Security key91 * <1-8 digits> #1 2 1295 Lock Dur

Strany 7 - High Current Lock Releases

C106 Keypad27Testing the controller with factory settingsBefore proceeding with this test ensure that the lock release is working correctlyby followin

Strany 8 - Programming the C106 Keypad

C106 KeypadSymptom Possible Cause/Remedy29The lock release fails tooperate when the Test buttonis pressedŽ Check the lock release and its wiringby mov

Strany 9

C106 Keypad31Specification for the C106 Controller Outputs LockOutput Voltage: Same as Input VoltageLoad (maximum): 0.5A (load inductive or resistive)

Strany 10

CS106 Combined SeriesCombined Door Entry and Coded AccessKeypadCS106 Combined Door Entry and Coded Access34General DescriptionThe CS106 series systems

Strany 11

CS106 Combined Door Entry and Coded Access35Installation of the Door Entryphone SystemFrom an electrical point of view, the combined systems may be re

Strany 12

C106 Keypad1FeaturesŽ Up to 10 codes each of 1 to 8 digits.Ž Two Time Zones for Staff/Executive operation.Ž Output for Fail-Safe and Fail-Secure locks

Strany 13 - Summary of Program Functions

CS106 Combined Door Entry and Coded Access37Cable RequirementsFor optimum clarity of speech it is strongly recommended that this system isinstalled u

Strany 14 - Commissioning

CS106 Combined Door Entry and Coded Access39TroubleshootingUse the table below to determine the most probable cause of a fault condition.Refer also to

Strany 15 - Troubleshooting

CS106 Combined Door Entry and Coded Access41Miscellaneous ProblemsSymptom Possible Cause/RemedyTelephone will not buzz.Ž Faulty'O' or &apos

Strany 16

CS106 Combined Door Entry and Coded Access43CS106 - N Wiring (Multi-way Combined)CS106 Combined Door Entry and Coded Access44Wiring Diagram - 2 Door S

Strany 17

C106 Keypad3Table 4 - Programming of Other Functions ... 25Commissioning ... 26Testing The

Strany 18 - CS106 Combined Series

C106 Keypad5Time-Restricted Access (Staff/Executive Operation)Any of the ten access codes may be programmed to operate during a restrictedtime period

Strany 19 - Cable Planning

C106 Keypad7InstallationRead carefully all of the information presented in this chapter and then install thesystem in accordance with the wiring diag

Strany 20 - Installation Procedure

C106 Keypad9Power Supply - Important Safety InformationThe Model 340 Power Supply must be wall-mounted on to plasterboard, woodor a similar non-condu

Strany 21

C106 Keypad11Electric Lock ReleaseWhen installing lock releases please allow a little movement on the door asoperation will be impaired if fitted too

Strany 22

C106 Keypad13Time Restricted Access The C105 Keypad has a pair of terminals marked ‘TIME’ which can be connectedto an external Time Clock or Key switc

Strany 23

C106 Keypad15Changing the Security key (Function 91)The security key is the code that must be entered on the keypad to gain accessto program mode.The

Komentáře k této Příručce