CS106/BL106 Combined Door Entry and Coded Access
13
Electric Lock Release
When installing lock releases please allow a little movement on the door as
operation will be impaired if fitted too tightly.
The C106 Keypad provides two alternative pairs of connections for direct
connection of an electric lock releases:-
‘FAIL SECR’
: Use these connections for ‘Fail-Secure’ lock releases. These
devices require power to release the lock and will secure the door in the event of
power failure. These are the most commonly used lock releases.
‘FAIL SAFE’:
Use these connections for ‘Fail-Safe’ lock releases and magnetic
locks. Both of these devices require continuous power to lock the door and will
release the door if power fails.
Note
Any magnetic lock (Maglock) must be fitted with a suitable transient voltage
suppressor, e.g. a diode or MOV. Please contact the manufacturer of the
Maglock to check
These outputs are rated at the input voltage (12V
) with a maximum current
consumption of 0.5A.