CS106/BL106 Combined Door Entry and Coded Access
14
High Current Lock Releases
For a lock release or a magnetic lock rated higher than 0.5A an additional power
supply will be required. In addition a relay must be used to interface with the
C106 Keypad.
The relay contacts, or the lock-release, must be fitted with a suitable
suppression device to prevent voltage transient and electromagnetic
interference being generated by the coil of the lock release. (Refer to
manufacturer for further advice).
Consideration should be given to the problem of a voltage drop at the lock
release. Please refer to the manufacturer of the particular lock release for
information on suitable cable length versus thickness and power supply rating.
High Current Lock Release
Zobrazit stránku 13